Operator’s Guide Inspector 4000™
002-5564 RJS, Minneapolis, MN
1. When Companion is enabled, data output is in the format of analysis only.
2. When Computer is enabled, data is output in computer readable format (text and
graphics). See Appendix C,
Computer Mode.
The next selection is:
Scans/Analysis
Single
From this screen you may choose the number of scans (from 1 (single) to 10) to be used
in the analysis.
The next selection is Decode 3of9 as:
Decode 3of9 as
ANSI 3of9
This selection is for choosing the Code 39 sub-specifications for analysis:
ANSI 3 of 9
3of9 w/43
AIAG B-1
AIAG B-3/4/5
LOGMARS
HIBC 3 of 9
Press Select to choose an option.
Press Enter to initiate processing for that option.
If either AIAG choice is entered, the Inspector 4000 will automatically perform the scan
reflectance profile analysis per the AIAG grading thresholds and display numbers 4, 3, 2,
1 and 0 in place of the letter grades.